VERTICAL REV-020A

Dehumidifier with ultra-high efficiency heat recovery, designed for use where both dehumidification and air renewal are required.

Neutral air version.

Equipped with a ModBus RS485 port for communication with RADIUS CONTROLS, a remotely operable terminal with a display for parameter settings, and a temperature and humidity sensor.

ACCESSORIES

CODICE

TITOLO

134_41KA000357

Display aggiuntivo

134_ETA01.139

Display montato a bordo macchina

134_41KA000077

Serrande motorizzate per controllo di rugiada ambiente

134_ETA01.125

Free cooling

41KA000169

Cavo schermato collegamento display L. 5 m

41KA000170

Cavo schermato collegamento display L. 10 m

41KA000171

Cavo schermato collegamento display L. 20 m

134_ETA02.104

Kit filtri ad alta efficienza

134_41KA000168

Sbrinamento automatico recuperatore, per temperatura aria esterna inferiore a -5°C

134_ETA02.103

Insonorizzazione compressore

134_ETA02.024

Funzione controllo temperatura di mandata modulante comprende sonda temperatura mandata e trasformatore per valvola

134_ETA02.025

Kit controllo temperatura di mandata modulante comprende sonda temperatura mandata, trasformatore valvola acqua e relativo servomotore

134_41KA000210

Plenum ricircolo REV Ø 160mm

134_41KA000269

Kit per canalizzazione del ricircolo Ø 160mm

134_41KA000202

Kit ricambio filtri aria Standard

134_41KA000275

Kit ricambio filtri aria alta efficienza

134_ETA01.133

Gabbia in legno

DATI TECNICI

Capacità deumidifica

L/giorno 24,5 (7-9 persone) (calore latente W/h 709)

Portata aria totale

m3/h 260

Portata aria rinnovo

m3/h 0-130

Rendimento recuperatore

> 90%

Prevalenza utile

Pa 170

Potenza frigorifera resa all’aria per integrazione

Isotermica

Potenza elettrica assorbita

W 1500 (max 2000)

Potenza frigorifera assorbita

W 250 (max 510)

Pressione sonora in campo libero a 1m, unità canalizzata

dB(A) 39

Alimentazione

V/ph/Hz 230/1+N/50

Dimensioni

mm 600 x 380 x H980

Peso

Kg 60

The air handling units (dehumidifiers and VMC) A|RADIUS allow for the completion of climate comfort functions according to the principles of Radiant Architecture at the most comprehensive level (Level III – see the “Radiant Climate Levels” sheet).
It is important to remember that the function of the dehumidifiers is NOT to prevent condensation on the panels (a function performed by the regulation independently of any type of air treatment) but rather to maintain a humidity level in the environment that ensures thermal comfort, even in cases of increased humidity from internal sources (e.g., people) or external sources (e.g., heat) to the building.
In the RADIUS system, dehumidification is carried out according to the BioSet logic, in which radiant temperature also plays a role in deciding when it is activated. This is because the need for evaporation from the body (and the body evaporates more when the humidity level is lower) also depends on the amount of radiation (and this occurs when the radiant temperature is lower, i.e., that of the surrounding surfaces).
In practice, with an average radiant temperature of 23°C, less dehumidification will be required than with a temperature of 25°C. This is why it is incorrect to activate dehumidification based solely on relative humidity, as it alone does not reflect the entire thermal exchange scenario available to the body in a specific context.
Thanks to this approach, dehumidification will be used more appropriately and economically.

PRINCIPI A | RADIUS BY ROBERTO MESSANA

The models and accessories are optimized for most residential and commercial conditions, in combination with all the variations of the RADIUS panels and the E|RADIUS controls. The units are standardly controlled via ModBus RS485 to enable remote monitoring, thereby facilitating management and maintenance services. Great care has been taken to ensure the units’ reliability and performance (efficiency, noise level, adjustability, and customization options).

SYSTEM ARCHITECTURE

The machine system is designed to offer all the necessary functions for complete air treatment in radiant air conditioning. The following combinations can be selected according to preference:

  • Only dehumidification with neutral air
  • Only dehumidification with neutral air or integration with cold air
  • Dehumidification with neutral air + air renewal with ultra-high efficiency recovery
  • Dehumidification with neutral air + integration with cold air + air renewal with ultra-high efficiency recovery
  • Only air renewal with ultra-high efficiency recovery

Therefore, depending on functional and economic needs, it is possible to choose the most suitable combination of functions.

FUNCTIONS

In the Technical Area at https://www.radiantarchitecture.it/download/download, you can find the manuals that provide detailed information on the features and performance of the models. For a thorough description, please refer to these manuals.

DESCRIPTION